CLEAN & WAX PROCEDURE
PRODUCTS REQUIRED
CLEANER (steam heated)
Cleana Form #1 or Cleana Form #5 or Iroclean Paste
Screenback 36" x 100" and Double Face Cotton Flannel
WAX (steam heated)
Karagami Powder Wax or Euroglide Wax or Cleana Cote
Wax N Clean Cloth or Cool N Clean Cloth
CLEANER and WAX (thermal oil heated & Steam)
High temperature ironers such as thermal oil heated, require a high
temperature cleaner and wax for the best results. These products
may also be used on lower temperature steam ironers. However,
they should not be mixed with lower temperature waxes.
Iroclean Paste Cleaner Euroglide Paste Wax
PROCEDURE
MONDAYS / WEDNESDAYS / FRIDAYS
1.Ironer should be at maximum heat.
2.Feed the Screenback Cleaner through the ironers entire surface.
3.Feed the Wax N Clean cloth through the ironers entire surface
without wax.
4.Feed the Wax N Clean cloth through the ironers entire surface a
second time with approximately 8 oz. of wax added to the cloth.
5.Feed the Wax N Clean cloth through the ironers entire surface
without any wax added every 2 hours of operation.
TUESDAYS / THURSDAYS
1.Ironer should be at maximum heat.
2.Feed the Screenback Cleaner through the ironers entire surface.
3.Roll the Double Face Cotton Flannel so that you can dip about 12"
of the length (ironer width) into Cleana Form #1. Wring the cloth
to remove excess cleaner and feed through the ironer.
4.Feed the Wax N Clean cloth through the ironers entire surface
without wax.
5.Feed the Wax N Clean cloth through the ironers entire surface a
Second time with approximately 8 oz. of wax added to the cloth.
6. Feed the Wax N Clean cloth through the ironers entire surface
without any wax added every 2 hours of operation.
NOTES
1. During the Clean and Wax procedure, always turn off the
vacuum system.
2. All folders in back of the ironers should be turned off.
3. Never apply wax to a cool chest and do not apply wax at
the end of the operation. A freshly waxed ironer has an
affinity for lint, which will carbonize if allowed to stand
without linens being processed.
4. When not in use, always store the Wax N Clean cloth in an
open area draped over a pipe stand for proper air circulation.
When the cloth becomes dirty, wash using medium water levels,
low extract and air dry.
5. The above procedure is only a guideline. Applications may
vary due to products processed and hours of operation.
|